Features :Radial leaded devices,Higher rated voltage up to 135V,UL94 V-0 insulating material, Agency Recognition: UL、CSA、TUV,Lead-free and compliant with the European Union RoHS Directive 2011/65/EU.
IH=Hold current: maximum current at which the device will not trip at 25℃ still air.
IT=Trip current: minimum current at which the device will always trip at 25℃ still air.
Vmax=Maximum voltage device can withstand without damage at rated current.
Imax=Maximum fault current device can withstand without damage at rated voltage.
Max Time-to-trip=Maximum time to trip(s) at assigned current.
Pd max=Maximum power dissipation: maximum power dissipated by the device when in state air environment.
Rmin=Minimum device resistance at 25℃ prior to tripping.
Rmax=Maximum device resistance at 25℃ prior to tripping.
R1max=Maximum device resistance at 25℃, of device one hour after being tripped the first time.